Metposite panel transverse load chart
|
Fasteners
per sq.ft. |
Transverse
load |
1.066* |
117** psf |
1.00 |
109.76
psf |
0.95 |
104.27
psf |
0.90 |
98.78
psf |
0.85 |
93.29
psf |
0.80 |
87.80
psf |
0.75 |
82.32
psf |
0.70 |
76.83
psf |
0.65 |
71.34
psf |
0.60 |
65.85psf |
0.55 |
60.37
psf |
0.50 |
54.88
psf |
0.45 |
49.39
psf |
0.40 |
43.90
psf |
0.35 |
38.41
psf |
0.3 |
32.93
psf |
|
* Base on 22.5 sq.ft test panel with corner fasteners and side fastened at 12" on center
|
** ASTM E-72 Structural Performance: Individual panel average ultimate load (held for one minute) 117lbs
|
***Testing Conducted By Intertek Testing Services NA Ltd. Complete report available on request
|
|
Fastener Requirement
|
Fastener to be evenly spaced on
fastening lip as required to achieve desired transverse load.
See examples below.
|
Formula: (desired transverse
load) x .0092 = (required screws per square foot)
|
|
Examples
|
Fastened 48" on center
|
48" x 48"
|
48" x 96"
|
48" x 120"
|
Number of screws
|
8
|
10
|
12
|
Fastener per square
|
0.5
|
0.3125
|
0.3
|
Transverse load (psf)
|
54.88
|
34.30
|
32.93
|
|
|
Fastened 32" on center
|
48" x 48"
|
48" x 96"
|
48" x 120"
|
Number of screws
|
12
|
14
|
16
|
Fastener per square
|
0.75
|
0.4375
|
0.4
|
Transverse load (psf)
|
82.32
|
48.02
|
43.90
|
|
|
Fastened 24" on center
|
48" x 48"
|
48" x 96"
|
48" x 120"
|
Number of screws
|
12
|
16
|
18
|
Fastener per square
|
0.75
|
0.5
|
0.45
|
Transverse load (psf)
|
82.32
|
54.88
|
49.39
|
|
|
Fastened 16" on center
|
48" x 48"
|
48" x 96"
|
48" x 120"
|
Number of screws
|
16
|
26
|
28
|
Fastener per square
|
1
|
0.8125
|
0.7
|
Transverse load (psf)
|
109.76
|
89.18
|
76.83
|
|
|
Fastened 12" on center
|
48" x 48"
|
48" x 96"
|
48" x 120"
|
Number of screws
|
20
|
28
|
36
|
Fastener per square
|
1.25
|
0.875
|
0.9
|
Transverse load (psf)
|
117+
|
96.04
|
98.78
|
|